ABUS Crane Eagle Error Code AB012

ABUS Crane Crane Major Hydraulic

Model: Eagle | Code: AB012

Applicable Systems
Eagle

Symptoms

System pressure has dropped below the low-pressure safety limit. The unit has shut down to prevent evaporator freeze damage.

Possible Causes

  • Refrigerant charge insufficient due to leak
  • Expansion valve restricted or failed
  • Evaporator water flow reduced or blocked

Troubleshooting Steps

  1. Step 1: Check refrigerant charge level and inspect for leaks
    Charge level correct, no leaks found
  2. Step 2: Inspect expansion valve operation and superheat
    Expansion valve operating within specification
  3. Step 3: Verify evaporator water flow rate and pump operation
    Flow rate meets design requirements

How to Reset

To reset: Reset the low-pressure switch after restoring adequate suction pressure.

Source: ABUS Crane Manual, ABUS Kransysteme GmbH

Category: Crane