B&R PLC Error Code 30004

B&R PLC & VFD Major Programming

Model: PLC | Code: 30004

Applicable Systems
PLC

Symptoms

The PLC reports a power module fault. The intelligent power module (IPM) detected an internal failure and tripped.

Possible Causes

  • IPM internal IGBT or freewheeling diode failure
  • IPM gate drive circuit fault preventing proper switching
  • IPM overheat due to excessive switching losses or cooling failure

Troubleshooting Steps

  1. Step 1: Check the IPM for short circuit between output terminals
    IPM shows no short circuit
  2. Step 2: Verify the cooling system is functioning and the heatsink is clean
    Cooling is adequate and heatsink is clean
  3. Step 3: If the IPM is defective, replace the drive unit
    New unit operates with a healthy IPM

How to Reset

To reset: Fix the power module fault or replace the unit, then restart.

Source: B&R Automation System Manual, B&R Industrial Automation

Category: PLC & VFD