Cummins PowerCommand Error Code 15

Cummins Generator Minor Power

Model: PowerCommand | Code: 15

Applicable Systems
PowerCommand

Symptoms

Warning - High battery voltage. The starting battery voltage is above the warning threshold.

Possible Causes

  • Battery charger voltage set too high
  • Charger voltage regulator failure

Troubleshooting Steps

  1. Step 1: Check the battery charging voltage
    Voltage exceeds the rated maximum
  2. Step 2: Adjust or replace the battery charger regulator
    Voltage is within the correct range

How to Reset

To reset: Fix the charger voltage, then acknowledge the warning.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Cummins Power Generation Control Manual, Cummins Inc.

Category: Generator