Applicable Systems
PowerCommand
Symptoms
Warning - Governor fault. The electronic governor is not controlling engine speed correctly.
Possible Causes
- Governor actuator failure
- Governor controller hardware fault
Troubleshooting Steps
- Step 1: Check the governor actuator operation
Actuator is not responding - Step 2: Verify the governor controller status
Controller reports an internal fault
How to Reset
To reset: Fix the governor actuator or controller, then acknowledge the warning.
Source: Cummins Power Generation Control Manual, Cummins Inc.
Category: Generator