Danfoss FC-302 Error Code 49

Danfoss PLC & VFD Major Brake

Model: FC-302 | Code: 49

Applicable Systems
FC-30 FC-51 FC-101 FC-202 FC-302

Symptoms

Brake chopper fault detected.

Possible Causes

  • Brake chopper IGBT failure
  • Brake resistor open circuit
  • Chopper control circuit fault

Troubleshooting Steps

  1. Step 1: Check brake resistor continuity
    Resistor within rated value
  2. Step 2: Inspect brake chopper IGBT
    IGBT not shorted
  3. Step 3: Verify chopper control circuit
    Control signal present

How to Reset

Reset via control panel after chopper repair.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Danfoss VLT FC-302 Operating Guide, Danfoss A/S

Category: PLC & VFD