Applicable Systems
Series 0i
Series 16/18/21
Alpha
Beta
Symptoms
A numerical value in the program exceeds the allowed limit.
Possible Causes
- A numerical value in the program exceeds the maximum allowed digits.
- Incorrect data entry in the NC program.
Troubleshooting Steps
- Step 1: Check the numerical values in the program for exceeding limits.
Offending values identified and corrected. - Step 2: Edit the program to use valid numerical ranges.
Program accepts the corrected values.
How to Reset
Correct the numerical value and reset to clear the alarm.
Comments (0)
Share your experience to help others facing the same problem.
Leave a Comment
Source: Fanuc 0i/0iMate Alarm Code List, FANUC Corporation