Fanuc 0i Error Code 015

Fanuc CNC Minor P/S Alarm

Model: FANUC Series 0i / 0i Mate | Code: 015

Applicable Systems
Series 0i Series 16/18/21 Alpha Beta

Symptoms

The number of simultaneously controlled axes exceeds the maximum allowed.

Possible Causes

  • The program commands more axes than the CNC can control simultaneously.
  • Incorrect axis configuration in the program.

Troubleshooting Steps

  1. Step 1: Check the number of axes commanded simultaneously.
    Excess axes identified.
  2. Step 2: Reduce the number of simultaneous axes to within the limit.
    Program executes within axis limits.

How to Reset

Correct the axis count and reset to clear the alarm.

Source: Fanuc 0i/0iMate Alarm Code List, FANUC Corporation

Category: CNC