Applicable Systems
Series 0i
Series 16/18/21
Alpha
Beta
Symptoms
The number of simultaneously controlled axes exceeds the maximum allowed.
Possible Causes
- The program commands more axes than the CNC can control simultaneously.
- Incorrect axis configuration in the program.
Troubleshooting Steps
- Step 1: Check the number of axes commanded simultaneously.
Excess axes identified. - Step 2: Reduce the number of simultaneous axes to within the limit.
Program executes within axis limits.
How to Reset
Correct the axis count and reset to clear the alarm.
Source: Fanuc 0i/0iMate Alarm Code List, FANUC Corporation
Category: CNC