Applicable Systems
Series 0i
Series 16/18/21
Alpha
Beta
Symptoms
An overcut condition was detected during tool nose radius compensation.
Possible Causes
- The programmed path would result in cutting into the workpiece.
- Tool radius too large for the programmed contour.
Troubleshooting Steps
- Step 1: Check the programmed contour against the tool nose radius.
Overcut condition identified. - Step 2: Reduce the tool nose radius or modify the contour.
Program executes without overcut.
How to Reset
Fix the overcut condition and reset to clear the alarm.
Comments (0)
Share your experience to help others facing the same problem.
Leave a Comment
Source: Fanuc 0i/0iMate Alarm Code List, FANUC Corporation
Category: CNC