Applicable Systems
Series 0i
Series 16/18/21
Alpha
Beta
Symptoms
A watchdog timer error was detected in the PMC. Alarm 057 is displayed on the CNC screen.
Possible Causes
- Programming error in the CNC part program
- Incorrect G/M code usage
- Parameter or offset data invalid
- Program format or syntax error
Troubleshooting Steps
- Step 1: Check the CNC alarm screen for alarm 057 details
Alarm message displayed with cause description - Step 2: Review the CNC part program for the block that caused the alarm
The problematic block is identified - Step 3: Correct the program, parameter, or offset data as indicated
The corrected value is accepted without error - Step 4: Press RESET to clear the alarm and re-run the program
Alarm clears and program runs without error
How to Reset
Press the RESET key on the CNC operator panel to clear the alarm after correcting the cause.
Frequently Asked Questions
- Q: What does Fanuc alarm 057 mean?
PMC Watchdog Error: A watchdog timer error was detected in the PMC.
- Q: How do I clear Fanuc alarm 057?
Correct the underlying cause (usually a program or parameter error), then press RESET on the CNC operator panel to clear the alarm.
Source: Fanuc 0i/0iMate Alarm Code List, FANUC Corporation
Category: CNC