Fanuc 0i Error Code 112

Fanuc CNC Minor P/S Alarm

Model: FANUC Series 0i / 0i Mate | Code: 112

Applicable Systems
Series 0i Series 16/18/21 Alpha Beta

Symptoms

A division by zero was attempted in a macro instruction.

Possible Causes

  • A macro variable used as a divisor has a value of zero.
  • Variable was not initialized or was set to zero.

Troubleshooting Steps

  1. Step 1: Check the divisor variable in the macro calculation.
    Zero divisor identified.
  2. Step 2: Assign a non-zero value to the divisor variable.
    Macro division executes without error.

How to Reset

Fix the division by zero and reset to clear the alarm.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Fanuc 0i/0iMate Alarm Code List, FANUC Corporation

Category: CNC