Applicable Systems
Series 0i
Series 16/18/21
Alpha
Beta
Symptoms
Y axis speed command exceeded the limit.
Possible Causes
- Commanded speed exceeds the maximum allowed value.
- Incorrect parameter setting or program error.
Troubleshooting Steps
- Step 1: Check speed-related parameters.
Parameter issue identified. - Step 2: Verify program commands are within speed limits.
Speed command corrected and alarm cleared.
How to Reset
Correct the speed command and reset to clear the alarm.
Comments (0)
Share your experience to help others facing the same problem.
Leave a Comment
Source: Fanuc 0i/0iMate Alarm Code List, FANUC Corporation