Fanuc FANUC 0i System Alarm 913

Fanuc CNC Critical Servo RAM parity (high)

Model: FANUC Series 0 / 0i / 30i | Code: 913

Applicable Systems
Series 0i Series 16/18/21 Alpha Beta

Symptoms

A parity error was detected in the higher byte of the digital servo shared RAM.

Possible Causes

  • RAM/ROM hardware failure
  • CPU malfunction
  • Watchdog timer expired
  • Power supply or fuse fault

Troubleshooting Steps

  1. Step 1: Record all alarm information displayed on the CNC screen
    Complete alarm information captured
  2. Step 2: Power cycle the CNC system
    System restarts; check if alarm clears
  3. Step 3: If alarm persists, check the main board and servo boards for visible damage
    No visible damage or burn marks
  4. Step 4: Replace the faulty main board or servo board as indicated by the alarm
    New board eliminates the system alarm

How to Reset

To reset system alarm 913: 1) Record all alarm information. 2) Power cycle the CNC. 3) If alarm persists, replace the indicated board (main board, servo board, etc.). 4) Re-load all system parameters and programs. Caution: System alarms indicate serious hardware faults; professional service is recommended.

Frequently Asked Questions

  • Q: What does 913 mean on Fanuc FANUC 0/0i/30i Series?

    A parity error was detected in the higher byte of the digital servo shared RAM.

  • Q: How do I fix 913 on Fanuc?

    Follow the troubleshooting steps: Record all alarm information displayed on the CNC screen

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: FANUC CNC System Alarm Manual (doc.eleok.com)