Applicable Systems
Series 0i
Series 16/18/21
Alpha
Beta
Symptoms
A digital servo local RAM parity error was detected.
Possible Causes
- Local RAM hardware fault in the digital servo system.
- Servo board component failure.
Troubleshooting Steps
- Step 1: Check the digital servo local RAM.
RAM fault identified. - Step 2: Replace the servo board if the local RAM is faulty.
Local RAM parity error cleared.
How to Reset
Fix the servo local RAM parity error and reset to clear the alarm.
Source: Fanuc 0i/0iMate Alarm Code List, FANUC Corporation
Category: CNC