Fanuc 0i Error Code OT 512 Y

Fanuc CNC Major Overtravel Alarm

Model: FANUC Series 0i / 0i Mate (Overtravel) | Code: OT 512 Y

Applicable Systems
Series 0i Series 16/18/21 Alpha Beta

Symptoms

The sub-axis has reached the positive (+) overtravel limit. Alarm OT 512 is displayed for the Y axis.

Possible Causes

  • Y axis moved beyond the physical or software travel limit
  • Y axis overtravel limit switch activated
  • Program error commanding axis beyond travel range
  • Work coordinate or tool offset error causing overtravel

Troubleshooting Steps

  1. Step 1: Identify which axis triggered the overtravel alarm (Y)
    The Y axis overtravel alarm is confirmed on the screen
  2. Step 2: Switch to jog mode and move the Y axis in the opposite direction away from the limit
    The axis moves away from the limit and the alarm can be reset
  3. Step 3: Press RESET to clear the overtravel alarm
    Alarm clears after axis is moved to a safe position
  4. Step 4: Review the program or offset data that caused the overtravel
    The problematic block or offset is identified and corrected

How to Reset

Move the axis away from the limit switch in the opposite direction, then press RESET to clear the alarm. For software overtravel, check and correct the travel limit parameters.

Frequently Asked Questions

  • Q: What does Fanuc OT 512 Y alarm mean?

    Overtravel (+) Sub: The sub-axis has reached the positive (+) overtravel limit. This indicates the Y axis has traveled beyond its allowed range.

  • Q: How do I clear Fanuc overtravel alarm 512?

    Switch to jog/handwheel mode, move the axis away from the limit in the opposite direction, then press RESET. If the axis cannot move, use the overtravel release switch (if equipped).

Source: Fanuc 0i/0iMate Overtravel Alarm Code List, FANUC Corporation