Symptoms

The servo control unit reports alarm SV 437 (CNV. OVERCURRENT POWER) on the 4th axis. The servo amplifier for the 4th axis may display an error state on its status LEDs. The axis may stop or fail to move until the condition is corrected.

Possible Causes

  • 4th axis servo amplifier fault: CNV. OVERCURRENT POWER
  • 4th axis servo amplifier wiring or connector issue
  • 4th axis servo amplifier power supply problem

Troubleshooting Steps

  1. Step 1: Check the 4th axis servo amplifier status LEDs and record the displayed state.
  2. Step 2: Verify all power and signal cables to the 4th axis servo amplifier are securely connected.
  3. Step 3: Measure the 4th axis amplifier DC link and control voltages per the maintenance manual.
  4. Step 4: If the 4th axis amplifier is faulty, replace it with a matching FANUC unit.

How to Reset

Power off the machine, correct the fault condition, power on, and press RESET. If the alarm reappears, service the servo amplifier.