Fanuc FANUC 0i Rigid Tapping Alarm SV0410

Fanuc CNC Info Servo excess error stop

Model: FANUC Series 0i (Rigid Tapping) | Code: SV0410

Applicable Systems
Series 0i Series 16/18/21 Alpha Beta

Symptoms

The position error when the tapping axis stops exceeds the set value.

Possible Causes

  • Rigid tapping program format error
  • Spindle or feed speed parameter error
  • Servo system fault during tapping
  • Ladder diagram signal processing error

Troubleshooting Steps

  1. Step 1: Check the rigid tapping program format (M29 Sxxxx G84/G74)
    Program follows correct format
  2. Step 2: Verify the spindle speed and feed rate parameters
    Speed and feed are within specification
  3. Step 3: Check the servo system for excess error alarms
    No servo excess error alarms present
  4. Step 4: Adjust the rigid tapping parameters (P5310, P5350, etc.) as needed
    Parameters set to correct values

How to Reset

To reset rigid tapping alarm SV0410: 1) Correct the program format or parameters. 2) Press RESET. 3) If servo-related, clear the servo alarm first. 4) Adjust rigid tapping parameters as needed. Caution: Rigid tapping requires precise spindle-feed synchronization; parameter adjustments should be done carefully.

Frequently Asked Questions

  • Q: What does SV0410 mean on Fanuc FANUC 0/0i/30i Series?

    The position error when the tapping axis stops exceeds the set value.

  • Q: How do I fix SV0410 on Fanuc?

    Follow the troubleshooting steps: Check the rigid tapping program format (M29 Sxxxx G84/G74)

Source: FANUC Rigid Tapping Alarm Codes (baijiahao.baidu.com)

Category: CNC