Applicable Systems
Fujitec Control System
Symptoms
Travel direction reversed from command direction
Possible Causes
- Encoder or wiring fault
- IF61 board fault
- inverter fault or setting error
- motor phase error
Troubleshooting Steps
- Step 1: Check encoder direction
Verify the fault is resolved after completing this step. - Step 2: verify wiring
Verify the fault is resolved after completing this step. - Step 3: inspect IF61
Verify the fault is resolved after completing this step. - Step 4: check inverter direction command
Verify the fault is resolved after completing this step. - Step 5: verify motor phases
Verify the fault is resolved after completing this step.
How to Reset
Power cycle after correction
Comments (0)
Share your experience to help others facing the same problem.
Leave a Comment
Source: baijiahao (huasheng fujitec); toutiao.com/w/1874164112328836
Category: Elevator