Fujitec GLVF-II Error GLVF03

Fujitec Elevator Major Controller

Model: GLVF-II | Code: GLVF03

Applicable Systems
Fujitec Control System

Symptoms

Fujitec GLVF-II elevator controller reports fault indicating control system or safety circuit issue requiring diagnostic evaluation of the elevator control and safety systems.

Possible Causes

  • Governor switch activation detected by the safety monitoring circuit
  • Door lock circuit interruption during travel mode operation
  • Counterweight safety switch signal lost during normal operation
  • Motor brake monitoring relay detected brake release failure

Troubleshooting Steps

  1. Step 1: Access GLVF-II controller diagnostic menu via maintenance panel
    Fault code, occurrence time, and status displayed on LCD
  2. Step 2: Check governor switch continuity at the governor assembly
    Governor switch shows closed circuit in normal operating condition
  3. Step 3: Verify door lock circuit integrity using multi-meter
    Door lock circuit shows 0 ohm resistance when doors are closed and locked
  4. Step 4: Test brake monitoring relay operation with manual brake test
    Relay activates within 0.5 seconds of brake command

How to Reset

Reset by: 1) Correct the fault condition. 2) Reset controller from maintenance mode. 3) Perform test run. 4) Verify normal operation before returning to service.

Common Replacement Parts

  • GLVF-CTL-001: Fujitec GLVF-II controller board assembly (Verify model compatibility before replacement)

Frequently Asked Questions

  • Q: What is the purpose of the governor switch?

    The governor switch monitors elevator overspeed and activates the safety gear if the car exceeds rated speed by 20%. The switch also provides a signal to the controller to remove drive power as an additional safety measure.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Fujitec GLVF-II Elevator Controller Manual

Category: Elevator