Gardner Denver Electra Saver Error Code G013

Gardner Denver Compressor Minor Control

Model: Electra Saver | Code: G013

Applicable Systems
Electra Saver

Symptoms

The controller displays a communication error between the main CPU board and the I/O expansion module. The alarm intermittently appears and resets.

Possible Causes

  • Loose ribbon cable between the CPU and I/O module
  • Electromagnetic interference on the communication bus
  • I/O module firmware version mismatch with the CPU

Troubleshooting Steps

  1. Step 1: Power down the controller and reseat the ribbon cable at both ends
    Ensure the cable is firmly inserted with no bent pins
  2. Step 2: Check the controller firmware version and I/O module version on the diagnostic screen
    Update the I/O module firmware if versions do not match
  3. Step 3: Verify the control panel door ground strap is intact and connected
    A missing ground strap allows EMI to disrupt communication

How to Reset

Reset: Power cycle the controller after reseating the cable. If the error persists, the I/O module may need replacement.

Common Replacement Parts

  • Ribbon cable: 26-pin, 150mm length (Match to controller model)
  • I/O expansion module: 8 digital in / 8 digital out (Verify firmware compatibility before ordering)

Frequently Asked Questions

  • Q: How do I check firmware versions?

    Navigate to Menu > Diagnostics > System Info on the controller display. Both CPU and I/O versions are listed.

  • Q: Can I run with a communication error?

    Intermittent errors may allow operation but I/O control is unreliable. Fix before relying on automatic mode.

Source: Service Manual

Category: Compressor