Grundfos Grundfos Pump Error Code 11

Grundfos Pump Major Power

Model: Grundfos Pump | Code: 11

Applicable Systems
MAGNA1

Symptoms

Phase reversed. The phase sequence of the three-phase supply is incorrect, causing reverse rotation.

Possible Causes

  • Phase wiring reversed during installation
  • Supply phase rotation changed by utility

Troubleshooting Steps

  1. Step 1: Check the pump rotation direction
    Pump is rotating in reverse
  2. Step 2: Swap two phase wires to correct the sequence
    Rotation direction is correct

How to Reset

To reset: Correct the phase sequence, then reset the controller.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Grundfos Pump Troubleshooting Guide, Grundfos Group

Category: Pump