Applicable Systems
MAGNA1
Symptoms
Temperature high. The liquid temperature exceeds the warning threshold.
Possible Causes
- Process temperature too high
- Insufficient cooling in the system
Troubleshooting Steps
- Step 1: Check the liquid temperature
Temperature exceeds the warning threshold - Step 2: Improve cooling or reduce the heat input
Temperature drops within range
How to Reset
To reset: Reduce the temperature, then reset the controller.
Comments (0)
Share your experience to help others facing the same problem.
Leave a Comment
Source: Grundfos Pump Troubleshooting Guide, Grundfos Group
Category: Pump
No comments yet. Be the first to share your experience!