Haas CNC Error Code 117

Haas CNC Major Overheat

Model: CNC | Code: 117

Applicable Systems
Haas CNC Mill (VF/VM Series)

Symptoms

Drive system overheat detected.

Possible Causes

  • Drive system temperature exceeded the safe operating limit.
  • Prolonged high-load operation without adequate cooling.

Troubleshooting Steps

  1. Step 1: Check the drive system cooling and ventilation.
    Cooling issue identified.
  2. Step 2: Improve cooling or reduce the operating load.
    Drive system temperature returns to normal.

How to Reset

Fix the drive overheating and reset to clear the alarm.

Source: Haas Alarm Codes, Haas Automation

Category: CNC