#5 ON fault - INV microcomputer shutdown

Hitachi Elevator Critical Elevator

Model: MCA | Code: 12

Applicable Systems
WJ200

Symptoms

#5 relay ON fault; inverter microcomputer stopped

Possible Causes

  • #5 relay failure
  • inverter microcomputer fault
  • communication between main and inverter CPU lost

Troubleshooting Steps

  1. Step 1: Check #5 relay
    Verify the fault is resolved after completing this step.
  2. Step 2: inspect inverter microcomputer
    Verify the fault is resolved after completing this step.
  3. Step 3: verify communication lines
    Verify the fault is resolved after completing this step.

How to Reset

Power cycle; replace relay/microcomputer if needed

Source: jxrunrui.cn/zhishi/1498.html; jingyan.baidu.com/article/a378c9...

Category: Elevator