Specification table abnormal

Hitachi Elevator Medium Elevator

Model: MCA | Code: 1B

Applicable Systems
WJ200

Symptoms

Specification table (parameter configuration) abnormal

Possible Causes

  • Parameter data corruption
  • specification table read error
  • EEPROM fault

Troubleshooting Steps

  1. Step 1: Verify parameter settings
    Verify the fault is resolved after completing this step.
  2. Step 2: re-program specification table
    Verify the fault is resolved after completing this step.
  3. Step 3: check EEPROM
    Verify the fault is resolved after completing this step.

How to Reset

Power cycle; re-program parameters

Source: jxrunrui.cn/zhishi/1498.html; jingyan.baidu.com/article/a378c9...