Huawei SUN2000 Error Code 103

Huawei PLC & VFD Major Grid

Model: SUN2000 | Code: 103

Applicable Systems
SUN2000

Symptoms

Grid overvoltage detected. The inverter measures a grid voltage that exceeds the maximum allowed inputvoltage rating. The inverter disconnects from the grid to protect internal components and comply with gridconnection standards.

Possible Causes

  • Grid voltage from the utility exceeds the inverter's maximum AC voltage rating
  • Grid impedance too high causing voltage rise during power feed-in
  • Inverter AC voltage measurement circuit calibration drift or sensor fault
  • Loose or high-resistance connection in the AC wiring causing local voltage rise

Troubleshooting Steps

  1. Step 1: Check the equipment status and fault indicators to confirm the active fault code
    Fault indicator or HMI displays code 103 as active
  2. Step 2: Verify all electrical connections, wiring harnesses, and connector seating
    All connections secure, no corrosion, loose pins, or damaged wires
  3. Step 3: Measure the input power supply voltage at the equipment terminals with a multimeter
    Voltage reading is within the equipment's specified operating range
  4. Step 4: Inspect the power input wiring, breakers, and fuses for damage or degradation
    Wiring intact, breakers closed, fuses continuous
  5. Step 5: Check for transient voltage events or power quality issues using a power analyzer
    No sustained overvoltage, undervoltage, or phase imbalance detected
  6. Step 6: Reset the fault after correcting the power issue: fix root cause, then press RESET or power-cycle
    Fault clears and equipment resumes normal operation

How to Reset

To reset: 1) Identify and fix the root cause described in the fault symptoms. 2) Press RESET on the HMI or controller, or power-cycle the equipment. 3) If the fault recurs, contact manufacturer service. Caution: Document the fault code and context before resetting.

Frequently Asked Questions

  • Q: What does fault code 103 mean on the Huawei SUN2000?

    Fault 103 on the Huawei SUN2000 indicates: Grid overvoltage detected. The inverter measures a grid voltage that exceeds the maximum allowed input voltage rating. The inverter disconnects from the grid to protect internal components and comply with grid connection standards. Refer to the equipment manual and manufacturer support for specific troubleshooting steps.

  • Q: Can I continue operating the equipment with fault 103 active?

    No. The equipment has detected a fault condition and has taken protective action (typically stopping or derating). Continuing to operate without fixing the root cause may cause further damage. Always investigate and fix the fault before resuming operation.

Source: Huawei SUN2000 Series Inverter User Manual, Huawei Official Support (support.huawei.com)

Category: PLC & VFD