Applicable Systems
SUN2000
Symptoms
PV input arc fault detected. The inverter's AFCI (Arc Fault Circuit Interrupter) has detected an arc fault onthe DC side. This is a fire risk and the inverter immediately disconnects.
Possible Causes
- Loose PV connector (MC4) causing arcing under load
- Damaged PV cable with intermittent contact causing arc
- Corroded PV junction box contact causing arc
- PV module internal cell string interconnect failure causing arc
Troubleshooting Steps
- Step 1: Check the equipment status and fault indicators to confirm the active fault code
Fault indicator or HMI displays code 125 as active - Step 2: Verify all electrical connections, wiring harnesses, and connector seating
All connections secure, no corrosion, loose pins, or damaged wires - Step 3: Check the system diagnostic buffer or event log for detailed fault information
Diagnostic buffer shows the specific fault cause and timestamp - Step 4: Verify power supply stability and environmental conditions
Power supply stable, environment within specifications - Step 5: Restart the equipment or power-cycle the control system
Equipment restarts and enters normal operating state - Step 6: Contact manufacturer support if the fault persists after all checks
Support provides specific troubleshooting guidance
How to Reset
To reset: 1) Identify and fix the root cause described in the fault symptoms. 2) Press RESET on the HMI or controller, or power-cycle the equipment. 3) If the fault recurs, contact manufacturer service. Caution: Document the fault code and context before resetting.
Frequently Asked Questions
- Q: What does fault code 125 mean on the Huawei SUN2000?
Fault 125 on the Huawei SUN2000 indicates: PV input arc fault detected. The inverter's AFCI (Arc Fault Circuit Interrupter) has detected an arc fault on the DC side. This is a fire risk and the inverter immediately disconnects. Refer to the equipment manual and manufacturer support for specific troubleshooting steps.
- Q: Can I continue operating the equipment with fault 125 active?
No. The equipment has detected a fault condition and has taken protective action (typically stopping or derating). Continuing to operate without fixing the root cause may cause further damage. Always investigate and fix the fault before resuming operation.
Source: Huawei SUN2000 Series Inverter User Manual, Huawei Official Support (support.huawei.com)