Kleemann K-Control Error KLM-E22

Kleemann Elevator Major Controller

Model: K-Control | Code: KLM-E22

Applicable Systems
K-Control

Symptoms

Kleemann K-Control elevator controller reports fault indicating control system issue requiring diagnostic evaluation of the elevator control system.

Possible Causes

  • Door motor encoder signal loss preventing precise door position control
  • Elevator level deviation exceeding 25mm during landing operation
  • Safety gear switch signal detected during normal speed operation
  • Motor thermal model calculation indicating winding temperature rise

Troubleshooting Steps

  1. Step 1: Access K-Control diagnostic via maintenance panel
    Fault code and description displayed
  2. Step 2: Check door motor encoder cable connection at motor
    Encoder cable firmly connected with no bent pins
  3. Step 3: Verify landing level accuracy with measuring tape
    Car floor level within 10mm of landing floor
  4. Step 4: Check safety gear switch operation during inspection speed test
    Switch remains closed during normal inspection speed operation

How to Reset

Reset by: 1) Correct the fault condition. 2) Reset controller. 3) Run test trip. 4) Verify normal operation.

Common Replacement Parts

  • KLM-CTL-001: Kleemann K-Control controller board (Verify model version)

Frequently Asked Questions

  • Q: How is landing level calibrated?

    Landing level is calibrated by adjusting the position learning data in the K-Control system. The elevator must complete a full travel learning run from bottom to top, stopping at each floor. The controller automatically calculates and stores the leveling parameters.

Source: Kleemann K-Control Technical Manual

Category: Elevator