Applicable Systems
MAZATROL MATRIX
MAZATROL Smooth
INTEGREX
Symptoms
The Mazak CNC control displays a lubrication alarm. The automatic lubrication system may not be operating.
Possible Causes
- Lubrication pump failure
- Lubrication level low
- Lubrication pressure switch fault
- Lubrication line blockage
- Lubrication timer fault
- Wiring harness or connector fault
Troubleshooting Steps
- Step 1: Record the Mazak alarm code 1106 and note the machine operating state
Alarm code and context are documented - Step 2: Access the alarm detail screen on the Mazatrol control for additional information
Detailed alarm information is retrieved - Step 3: Inspect the Lubrication subsystem for visible faults, damage, or abnormal conditions
No visible damage or abnormalities found - Step 4: Check parameters, programs, and offsets per the Mazak service manual
Values match expected settings or discrepancies are identified - Step 5: Reset the alarm per the Mazak procedure and test machine operation
Alarm clears and machine operates normally, or alarm returns
How to Reset
To reset Mazak alarm 1106: 1) Resolve the underlying fault per the troubleshooting steps. 2) Press the RESET key on the Mazatrol control panel. 3) If the alarm persists, press EMERGENCY STOP, release it, then press RESET. 4) If still present, power cycle the machine (main breaker off, wait 30 seconds, on). 5) Contact Mazak service if the alarm persists after reboot.
Frequently Asked Questions
- Q: What does Mazak alarm 1106 mean?
Alarm 1106 indicates: Lubrication Alarm #107. This is a Mazak MAZATROL control system alarm related to Lubrication.
- Q: How do I clear Mazak alarm 1106?
Fix the root cause, press RESET. If persistent, cycle E-STOP and RESET. If still present, power cycle the machine. Contact Mazak service if it returns.
- Q: Is Mazak alarm 1106 critical?
Severity: Minor. Monitor and service at next opportunity.
Source: Mazak MAZATROL Alarm List / Mazak Service Manual
Category: CNC