Applicable Systems
Mitsubishi Elevator
Symptoms
Leveling position abnormality detected at stop
Possible Causes
- Leveling sensor fault
- position error at floor level
- floor data drift
- rope slip
Troubleshooting Steps
- Step 1: Check leveling sensor
Verify the fault is resolved after completing this step. - Step 2: verify floor data
Verify the fault is resolved after completing this step. - Step 3: inspect ropes
Verify the fault is resolved after completing this step. - Step 4: re-run floor learning
Verify the fault is resolved after completing this step.
How to Reset
Power cycle; re-run floor learning
Source: baike.baidu.com; baijiahao (三菱故障代码); diantijob.com
Category: Elevator