Applicable Systems
Mitsubishi Elevator
Symptoms
Reverse running detected - direction opposite to command
Possible Causes
- Motor phase reversed
- inverter direction command error
- encoder direction signal error
- brake slip
Troubleshooting Steps
- Step 1: Check motor phase sequence
Verify the fault is resolved after completing this step. - Step 2: verify inverter direction
Verify the fault is resolved after completing this step. - Step 3: inspect encoder direction
Verify the fault is resolved after completing this step. - Step 4: check brake
Verify the fault is resolved after completing this step.
How to Reset
Power cycle after correction
Comments (0)
Share your experience to help others facing the same problem.
Leave a Comment
Source: baike.baidu.com; baijiahao (三菱故障代码); diantijob.com