Applicable Systems
OBD-II
Symptoms
The signal is intermittent, dropping out or spiking sporadically. The fault may not be present at all times.
Possible Causes
- Loose or corroded connector causing intermittent contact
- Wiring harness flexing causing momentary opens
- Sensor internal intermittent failure
Troubleshooting Steps
- Step 1: Wiggle test wiring harness and connectors while monitoring signal
Signal drops out during test - Step 2: Inspect connectors for corrosion and loose pins
Connector repaired or replaced - Step 3: Replace sensor if intermittent operation persists
Signal stable after replacement
How to Reset
To reset: Clear the DTC after securing all connections and verifying stable signal.
Comments (0)
Share your experience to help others facing the same problem.
Leave a Comment
Source: SAE J2012 OBD-II Diagnostic Trouble Codes, SAE International
Category: OBD-II
Published: 2026-10-07