Applicable Systems
OBD-II

Symptoms

Bank 2 catalytic converter efficiency below threshold; post-cat O2 on bank 2 switching like pre-cat.

Possible Causes

  • Bank 2 catalytic converter degraded
  • Bank 2 post-cat O2 sensor faulty
  • Exhaust leak on bank 2

Troubleshooting Steps

  1. Step 1: Compare bank 2 pre and post-cat O2 sensors
    Post-cat should be steady
  2. Step 2: Check for bank 2 exhaust leaks
    No leaks
  3. Step 3: Verify bank 2 O2 sensors operational
    Sensors switching normally
  4. Step 4: Replace bank 2 catalytic converter if confirmed degraded
    Post-cat O2 steady
  5. Step 5: Clear code and verify with drive cycle
    No P0430 return

How to Reset

Clear with OBD-II scanner; requires drive cycle to verify.

Common Replacement Parts

  • Catalytic Converter Bank 2 (OEM spec)

Frequently Asked Questions

  • Q: Do both cats need replacement?

    Only replace the failing bank's cat. But if one cat failed due to age/miles, the other may not be far behind. Consider both if high mileage.

Source: SAE J2012 standard DTC list + OBD-II portal

Category: OBD-II