OBD-II Error Code P1419 - Oxygen Sensor Bank 1 Sensor 2 Circuit High

OBD-II Standard OBD-II Major O2 Sensor

Model: SAE J2012 Extended | Code: P1419

Applicable Systems
OBD-II

Symptoms

The downstream oxygen sensor for bank 1 signal is above expected.

Possible Causes

  • O2 sensor bank 1 sensor 2 failed high
  • Wiring shorted to power
  • Connector damaged
  • Sensor disconnected
  • ECM pull-up fault

Troubleshooting Steps

  1. Step 1: Connect an OBD-II scan tool and read all stored DTCs and freeze frame data
    All DTCs and freeze frame data are retrieved
  2. Step 2: Inspect the related sensor or actuator wiring for damage, corrosion, or loose connections
    Wiring and connectors are in good condition
  3. Step 3: Use a digital multimeter to check sensor voltage, resistance, and reference signals per manufacturer specifications
    Values are within specified range
  4. Step 4: Perform component-level testing of the suspected sensor or actuator
    Component passes or fails definitively
  5. Step 5: Clear codes and road test to verify repair
    Code does not return and system operates normally

How to Reset

To reset code P1419: 1) Repair the underlying fault. 2) Use an OBD-II scan tool to clear the DTC. 3) Perform a drive cycle.

Frequently Asked Questions

  • Q: What does OBD-II code P1419 mean?

    Code P1419 indicates: Oxygen Sensor Bank 1 Sensor 2 Circuit High. This is a Toyota manufacturer-specific diagnostic trouble code.

  • Q: Is code P1419 serious?

    Severity: Major. Service as needed.

  • Q: How do I fix code P1419?

    Diagnose the O2 Sensor system and replace faulty components.

Source: OBD-II Manufacturer Extended Codes / SAE J2012 / OBD-Codes.com

Category: OBD-II