Otis Gen2/SkyRise Error Code 0005

Otis Elevator Critical Safety

Model: Gen2/SkyRise | Code: 0005

Applicable Systems
SKY-2

Symptoms

The elevator reports a governor overspeed trip. The speed governor has detected an overspeed condition.

Possible Causes

  • Car speed exceeding the governor trip setpoint
  • Governor calibration drift
  • Governor rope slipping on the sheave

Troubleshooting Steps

  1. Step 1: Verify the governor trip speed setting
    Setting matches the car specification
  2. Step 2: Check governor rope condition and tension
    Rope is in good condition with proper tension
  3. Step 3: Test the governor function with a speed test
    Governor trips at the correct speed

How to Reset

To reset: Reset the governor trip mechanism, then reset the controller.

Source: Otis Elevator Service Manual, Otis Worldwide Corporation

Category: Elevator