Otis Gen2/SkyRise Error Code 0018

Otis Elevator Minor Safety

Model: Gen2/SkyRise | Code: 0018

Applicable Systems
SKY-2

Symptoms

The elevator reports an emergency lighting activation. The emergency battery lighting has been activated.

Possible Causes

  • Main power supply interruption
  • Emergency lighting battery charged and functional
  • Automatic transfer switch operated correctly

Troubleshooting Steps

  1. Step 1: Verify the main power supply is restored
    Power is stable and restored
  2. Step 2: Check the emergency lighting battery charge
    Battery is fully charged
  3. Step 3: Verify the automatic transfer switch resets
    Switch returns to normal position

How to Reset

To reset: Restore main power, then clear the emergency lighting alarm.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Otis Elevator Service Manual, Otis Worldwide Corporation

Category: Elevator