Rexroth IndraDrive HCS Error Code F7014

Rexroth PLC & VFD Major Safety

Model: IndraDrive HCS | Code: F7014

Applicable Systems
EFC FEX FEI HNC

Symptoms

Safe acceleration peak exceeded. The safety system has detected that the motor acceleration exceeded the configured safe acceleration peak limit.

Possible Causes

  • Acceleration setpoint too aggressive
  • Load inertia lower than expected causing higher actual acceleration
  • Controller gain too high producing acceleration overshoot
  • Safe acceleration limit set too low for the application

Troubleshooting Steps

  1. Step 1: Check the safe acceleration peak limit parameter
    Acceleration limit matches the machine safety assessment
  2. Step 2: Review the acceleration setpoint in the motion profile
    Setpoint acceleration is within the safe limit
  3. Step 3: Verify actual load inertia matches the design value
    Actual inertia matches calculated value
  4. Step 4: Adjust acceleration limit or motion profile after safety review
    Acceleration stays within safe limits during all modes

How to Reset

1) Check safe acceleration limit. 2) Review motion profile. 3) Verify load inertia. 4) Adjust parameters after safety review.

Frequently Asked Questions

  • Q: Why does the safety system monitor acceleration?

    Excessive acceleration can cause mechanical stress, load shifting, or loss of workpiece grip. The safety system ensures acceleration stays within limits determined by the machine safety assessment.

  • Q: How do I set the safe acceleration limit?

    Calculate based on mechanical component ratings, load stability requirements, and grip/holding force analysis. Document the calculation in the safety assessment file.

Source: Rexroth IndraDrive Safety Integrated Manual, Bosch Rexroth AG

Category: PLC & VFD