Door opening timeout (12s)

Schindler Elevator Medium Elevator

Model: Bionic/3300 | Code: 0302

Applicable Systems
Schindler Control System

Symptoms

Door did not open within 12 seconds

Possible Causes

  • Door motor fault
  • door mechanism jammed
  • door open limit switch fault

Troubleshooting Steps

  1. Step 1: Check door motor
    Verify the fault is resolved after completing this step.
  2. Step 2: inspect door mechanism
    Verify the fault is resolved after completing this step.
  3. Step 3: verify door open limit switch
    Verify the fault is resolved after completing this step.

How to Reset

Power cycle after repair

Source: book118 Bionic 3300 diagnostic manual; diantijob.com/175389.html

Category: Elevator