SEW Movidrive MDX61A Error Code F15

SEW PLC & VFD Major Brake

Model: Movidrive MDX61A | Code: F15

Applicable Systems
MoviDrive

Symptoms

Brake resistor overtemperature: brake resistor too hot.

Possible Causes

  • Brake resistor undersized
  • Excessive regenerative duty
  • Resistor cooling inadequate

Troubleshooting Steps

  1. Step 1: Check resistor sizing
    Resistor properly sized
  2. Step 2: Reduce regenerative duty
    Duty within rated range
  3. Step 3: Improve resistor cooling
    Temperature within range

How to Reset

Reset via control panel after resistor cools.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: SEW Movidrive MDX61A System Manual, SEW-EURODRIVE

Category: PLC & VFD