Applicable Systems
S7-1200
S7-1500
S7-300
S7-400
LOGO!
SINAMICS
Symptoms
Internal software error. The V90 has detected an internal firmware fault that requires attention. The drive enters a safe state and stops the motor.
Possible Causes
- Firmware bug or corruption
- Internal parameter set corruption
- Control board memory error
- Firmware version incompatibility with hardware revision
Troubleshooting Steps
- Step 1: Power-cycle the V90 (remove and reapply power)
If F1015 clears, it was a transient firmware issue; monitor for recurrence - Step 2: If F1015 returns, reload the firmware via Siemens TIA Portal
Firmware update completes; V90 initializes normally - Step 3: Verify the firmware version is compatible with the hardware revision
Firmware version matches the V90 hardware revision per Siemens compatibility matrix - Step 4: If firmware reload does not resolve, the control board has a hardware defect
Drive replacement required
How to Reset
1) Power cycle. 2) Reload firmware. 3) Verify compatibility. 4) Replace drive if persistent. Caution: Do not interrupt power during firmware updates.
Frequently Asked Questions
- Q: How do I update V90 firmware?
In TIA Portal: Online & Diagnostics > Drive > Firmware Update. Select the firmware file (.frm) and follow the wizard. Ensure stable power throughout the process.
- Q: Can I downgrade V90 firmware?
Generally no. Siemens does not support firmware downgrades for V90. Always use the latest firmware version compatible with your hardware revision.
Comments (0)
Share your experience to help others facing the same problem.
Leave a Comment
Source: Siemens SINAMICS V90 Operating Instructions, Edition 01/2023