Siemens SINAMICS V90 Error Code F1015

Siemens PLC & VFD Major System

Model: SINAMICS V90 | Code: F1015

Applicable Systems
S7-1200 S7-1500 S7-300 S7-400 LOGO! SINAMICS

Symptoms

Internal software error. The V90 has detected an internal firmware fault that requires attention. The drive enters a safe state and stops the motor.

Possible Causes

  • Firmware bug or corruption
  • Internal parameter set corruption
  • Control board memory error
  • Firmware version incompatibility with hardware revision

Troubleshooting Steps

  1. Step 1: Power-cycle the V90 (remove and reapply power)
    If F1015 clears, it was a transient firmware issue; monitor for recurrence
  2. Step 2: If F1015 returns, reload the firmware via Siemens TIA Portal
    Firmware update completes; V90 initializes normally
  3. Step 3: Verify the firmware version is compatible with the hardware revision
    Firmware version matches the V90 hardware revision per Siemens compatibility matrix
  4. Step 4: If firmware reload does not resolve, the control board has a hardware defect
    Drive replacement required

How to Reset

1) Power cycle. 2) Reload firmware. 3) Verify compatibility. 4) Replace drive if persistent. Caution: Do not interrupt power during firmware updates.

Frequently Asked Questions

  • Q: How do I update V90 firmware?

    In TIA Portal: Online & Diagnostics > Drive > Firmware Update. Select the firmware file (.frm) and follow the wizard. Ensure stable power throughout the process.

  • Q: Can I downgrade V90 firmware?

    Generally no. Siemens does not support firmware downgrades for V90. Always use the latest firmware version compatible with your hardware revision.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Siemens SINAMICS V90 Operating Instructions, Edition 01/2023

Category: PLC & VFD

Published: 2026-11-02