Universal Robots CB3 Error Code C200A25: 24V voltage is too high

Universal Robots Robot Minor Power

Model: CB3 (UR3/UR5/UR10) | Code: C200A25

Applicable Systems
UR3 UR5 UR10 UR3e UR5e UR10e UR16e UR20 UR30

Symptoms

24V voltage is too high

Troubleshooting Steps

  1. Step 1: Check external 24 V and Safety Control Board for issues,
    Check if the issue is resolved after this step
  2. Step 2: Conduct a complete rebooting sequence,
    Check if the issue is resolved after this step
  3. Step 3: If this happens more than twice in a row, replace Safety Control Board.
    Check if the issue is resolved after this step

How to Reset

Power cycle the robot controller and perform a complete reboot sequence. If the error persists, update the software to the latest version.

Source: Universal Robots Official Error Codes Directory (https://www.universal-robots.com/manuals/EN/PDF/Shared/ErrorCodes/ErrorCodes.pdf)

Category: Robot