Applicable Systems
UR3
UR5
UR10
UR3e
UR5e
UR10e
UR16e
UR20
UR30
Symptoms
The PROFIsafe submodule id received from the PROFIsafe host does not match the control operational mode setting in the Polyscope PROFIsafe configuration
Possible Causes
- The PROFIsafe submodule id received from the PROFIsafe host does not match the control operational mode setting in the Polyscope PROFIsafe configuration
Troubleshooting Steps
- Step 1: Check the selected submodule in the PROFIsafe host and the control operational mode setting in the Polyscope PROFIsafe configuration,
Check if the issue is resolved after this step - Step 2: Conduct a complete rebooting sequence,
Check if the issue is resolved after this step - Step 3: Contact your local Universal Robots service provider for assistance
Check if the issue is resolved after this step
How to Reset
Power cycle the robot controller and perform a complete reboot sequence. If the error persists, update the software to the latest version.
Source: Universal Robots Official Error Codes Directory (https://www.universal-robots.com/manuals/EN/PDF/Shared/ErrorCodes/ErrorCodes.pdf)
Category: Robot