Universal Robots CB3 Error Code C55A51: Voltage will not disappear from robot

Universal Robots Robot Minor Power

Model: CB3 (UR3/UR5/UR10) | Code: C55A51

Applicable Systems
UR3 UR5 UR10 UR3e UR5e UR10e UR16e UR20 UR30

Symptoms

Safety Control Bord hardware fault

Possible Causes

  • Safety Control Bord hardware fault

Troubleshooting Steps

  1. Step 1: Conduct a complete rebooting sequence,
    Check if the issue is resolved after this step
  2. Step 2: If this happens more than twice in a row, replace Safety Control Board
    Check if the issue is resolved after this step

How to Reset

Power cycle the robot controller and perform a complete reboot sequence. If the error persists, update the software to the latest version.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Universal Robots Official Error Codes Directory (https://www.universal-robots.com/manuals/EN/PDF/Shared/ErrorCodes/ErrorCodes.pdf)

Category: Robot