Applicable Systems
UR3
UR5
UR10
UR3e
UR5e
UR10e
UR16e
UR20
UR30
Symptoms
The load current exceeded safe limits, or an inductive load issue was detected
Possible Causes
- The load current exceeded safe limits, or an inductive load issue was detected
Troubleshooting Steps
- Step 1: Reduce the load current and let the system cool,
Check if the issue is resolved after this step - Step 2: For load currents above 600mA, the inductive clamping energy must be limited to 0.3 Joule,
Check if the issue is resolved after this step - Step 3: Contact your local Universal Robots service provider for assistance
Check if the issue is resolved after this step
How to Reset
Power cycle the robot controller and perform a complete reboot sequence. If the error persists, update the software to the latest version.
Source: Universal Robots Official Error Codes Directory (https://www.universal-robots.com/manuals/EN/PDF/Shared/ErrorCodes/ErrorCodes.pdf)
Category: Robot