Applicable Systems
EC220 Excavator
Symptoms
The swing gear oil level is low, and the swing reducer temperature has risen above 80C (176F). The controller logs a swing system warning.
Possible Causes
- Swing reducer oil leak from the output shaft seal
- Swing gear oil contaminated with water or debris
- Swing brake dragging, causing excessive heat generation
- Swing motor bearing wear increasing friction
Troubleshooting Steps
- Step 1: Check the swing gear oil level at the inspection plug and inspect for leaks
Top up with SAE 80W-90 gear oil and repair the output seal if leaking - Step 2: Drain a small oil sample and inspect for water contamination or metal particles
If contaminated, drain and refill the entire swing reducer - Step 3: Test the swing brake release by measuring brake pressure during swing operation
Brake should fully release at the rated pressure; if not, inspect the brake piston seals - Step 4: Measure the swing reducer temperature with an infrared thermometer during operation
If above 80C, reduce swing cycle frequency and allow cooling
How to Reset
Reset: The warning clears once the swing reducer temperature drops below 70C and oil level is restored.
Common Replacement Parts
- Swing gear oil: SAE 80W-90, GL-5 specification (Capacity: approximately 6-12L)
- Swing reducer seal kit: Output shaft seal and O-rings (Use OEM kit for correct fit)
- Swing brake piston seal: High-pressure hydraulic seal (Check material compatibility with oil)
Frequently Asked Questions
- Q: How often should swing gear oil be changed?
First change at 500 hours, then every 2000 hours. Sample the oil annually for contamination.
- Q: What causes swing brake dragging?
Contaminated brake plates, seized release piston, or low brake release pressure. Inspect and service the brake assembly.