Applicable Systems
Golf
Jetta
Passat
Tiguan
Audi A4
Symptoms
DPF pressure sensor signal implausible; DPF regeneration may not initiate.
Possible Causes
- DPF pressure sensor signal out of range
- DPF pressure tube clogged or damaged
- DPF substrate excessive ash accumulation
Troubleshooting Steps
- Step 1: Check DPF pressure sensor wiring
Wiring intact, no corrosion - Step 2: Compare actual vs commanded DPF pressure
Pressure differential within spec - Step 3: Replace DPF pressure sensor or clean DPF
Component replaced or DPF cleaned
How to Reset
Clear codes and perform DPF regeneration cycle.
Source: SAE J2012 Standard, OBD-II Service Manuals
Category: OBD-II