Worcester Bosch Greenstar GB162 Error Code E9

Worcester Bosch Home Boiler Critical HeatExchanger

Model: Greenstar GB162 | Code: E9

Applicable Systems
Greenstar GB162

Symptoms

The Worcester Bosch Greenstar boiler displays fault code E9, indicating overheating. The boiler has shut down because a safety temperature limiter has detected that the heat exchanger or system temperature exceeds the safe limit.

Possible Causes

  • System circulation pump failed or running at reduced speed
  • System filter or pipework blocked restricting water flow through the heat exchanger
  • Air in the heating system causing poor circulation
  • Temperature limiter (safety thermostat) faulty giving false reading

Troubleshooting Steps

  1. Step 1: Check system pressure on the boiler pressure gauge
    Pressure must be between 1.0 and 2.0 bar when cold; repressurize if below 1.0 bar using the filling loop
  2. Step 2: Verify circulation pump is running and not blocked
    Pump should vibrate slightly when running; check for seized pump or air lock
  3. Step 3: Bleed radiators and check for air in the heating system
    Air in the system causes circulation problems; bleed all radiators starting from the lowest
  4. Step 4: Inspect system filter and magnetic sludge separator for blockage
    Clean or replace filter elements; sludge buildup restricts flow and causes overheating

How to Reset

To reset: 1) Press and hold the Reset button on the boiler fascia for approximately 5 seconds. 2) The boiler should restart. 3) If E9 returns, the overheating cause must be investigated by a Gas Safe registered engineer. Caution: Repeated E9 faults indicate a circulation problem that can damage the heat exchanger permanently.

Frequently Asked Questions

  • Q: What temperature triggers E9 on a Worcester Bosch boiler?

    E9 triggers when the safety temperature limiter detects the heat exchanger temperature exceeds approximately 95-105C. The exact threshold varies by model.

  • Q: Can I reset E9 myself?

    Yes, you can press the reset button. However, if E9 recurs, you must contact a Gas Safe registered engineer. Repeated overheating can cause permanent heat exchanger damage and is a safety concern.

Source: Worcester Bosch GB162 Installation and Servicing Instructions, Fault Code E9, Worcester Bosch UK Documentation

Category: Home Boiler