Yaskawa bCE: Bluetooth communication fault

Yaskawa Electrical Fault vfd

Model: GA700/A1000 | Code: bCE

Applicable Systems
GA700 GA500 A1000 V1000 J1000

Symptoms

Bluetooth communication fault

Possible Causes

  • DriveWizard Mobile or DriveWizard controller too far from operator
  • Other device radio interference on 2400-2480 MHz band

Troubleshooting Steps

  • Move controller within 10m of operator
  • Check for interfering wireless devices on 2400-2480 MHz band
  • Set o2-27 for bluetooth communication interruption action

How to Reset

Reset by: 1) Correct the fault condition. 2) Press RESET button on operator panel. 3) Verify fault does not recur.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Yaskawa GA700 Fault Code Manual (jinxinservice.com)