Yaskawa dv1: Z-phase pulse loss detection

Yaskawa Electrical Fault vfd

Model: GA700/A1000 | Code: dv1

Applicable Systems
GA700 GA500 A1000 V1000 J1000

Symptoms

Z-phase pulse loss detection

Possible Causes

  • PG option card or motor-side PG damaged
  • PG cable wiring incorrect or broken

Troubleshooting Steps

  • Check PG cable wiring and breaks; correct if needed
  • Ground PG cable shield properly
  • Restart drive
  • If fault persists, replace PG option card or PG

How to Reset

Reset by: 1) Correct the fault condition. 2) Press RESET button on operator panel. 3) Verify fault does not recur.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Yaskawa GA700 Fault Code Manual (jinxinservice.com)

Category: Electrical