Yaskawa dv2: Z-phase noise abnormal detection

Yaskawa Electrical Fault vfd

Model: GA700/A1000 | Code: dv2

Applicable Systems
GA700 GA500 A1000 V1000 J1000

Symptoms

Z-phase noise abnormal detection

Possible Causes

  • PG cable noise interference
  • PG cable wiring incorrect or broken
  • 24+ pole motor at zero speed
  • PG option card or motor-side PG damaged

Troubleshooting Steps

  • Route PG cable away from drive output lines
  • Check PG cable wiring/breaks; ground shield properly
  • Set F1-46=1 for mechanical angle detection; adjust F1-17/F1-47 thresholds
  • Restart drive; if persists, replace PG card or PG

How to Reset

Reset by: 1) Correct the fault condition. 2) Press RESET button on operator panel. 3) Verify fault does not recur.

Comments (0)

Share your experience to help others facing the same problem.

No comments yet. Be the first to share your experience!

Leave a Comment

Source: Yaskawa GA700 Fault Code Manual (jinxinservice.com)

Category: Electrical