1-1 |
Caterpillar Heavy Equipment
|
Caterpillar CID 1 FMI 1 - Mechanical Engine Speed Sensor Data Valid But Below Normal Range |
heavy-equipment |
Major |
View → |
1-13 |
Caterpillar Heavy Equipment
|
Caterpillar CID 1 FMI 13 - Mechanical Engine Speed Sensor Out of Calibration |
heavy-equipment |
Minor |
View → |
1-15 |
Caterpillar Heavy Equipment
|
Caterpillar CID 1 FMI 15 - Mechanical Engine Speed Sensor Data Valid But Above Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
1-16 |
Caterpillar Heavy Equipment
|
Caterpillar CID 1 FMI 16 - Mechanical Engine Speed Sensor Data Valid But Above Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
1-3 |
Caterpillar Heavy Equipment
|
Caterpillar CID 1 FMI 3 - Mechanical Engine Speed Sensor Voltage Above Normal/Shorted High |
heavy-equipment |
Major |
View → |
1-6 |
Caterpillar Heavy Equipment
|
Caterpillar CID 1 FMI 6 - Mechanical Engine Speed Sensor Current Above Normal/Grounded Circuit |
heavy-equipment |
Major |
View → |
10-1 |
Caterpillar Heavy Equipment
|
Caterpillar CID 10 FMI 1 - Fuel Pressure Sensor Data Valid But Below Normal Range |
heavy-equipment |
Major |
View → |
10-13 |
Caterpillar Heavy Equipment
|
Caterpillar CID 10 FMI 13 - Fuel Pressure Sensor Out of Calibration |
heavy-equipment |
Minor |
View → |
10-15 |
Caterpillar Heavy Equipment
|
Caterpillar CID 10 FMI 15 - Fuel Pressure Sensor Data Valid But Above Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
10-16 |
Caterpillar Heavy Equipment
|
Caterpillar CID 10 FMI 16 - Fuel Pressure Sensor Data Valid But Above Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
10-18 |
Caterpillar Heavy Equipment
|
Caterpillar CID 10 FMI 18 - Fuel Pressure Sensor Data Valid But Below Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
10-2 |
Caterpillar Heavy Equipment
|
Caterpillar CID 10 FMI 2 - Fuel Pressure Sensor Data Erratic/Intermittent |
heavy-equipment |
Minor |
View → |
10-3 |
Caterpillar Heavy Equipment
|
Caterpillar CID 10 FMI 3 - Fuel Pressure Sensor Voltage Above Normal/Shorted High |
heavy-equipment |
Major |
View → |
10-5 |
Caterpillar Heavy Equipment
|
Caterpillar CID 10 FMI 5 - Fuel Pressure Sensor Current Below Normal/Open Circuit |
heavy-equipment |
Major |
View → |
10-6 |
Caterpillar Heavy Equipment
|
Caterpillar CID 10 FMI 6 - Fuel Pressure Sensor Current Above Normal/Grounded Circuit |
heavy-equipment |
Major |
View → |
10-8 |
Caterpillar Heavy Equipment
|
Caterpillar CID 10 FMI 8 - Fuel Pressure Sensor Abnormal Frequency/Pulse Width |
heavy-equipment |
Major |
View → |
100-13 |
Caterpillar Heavy Equipment
|
Caterpillar CID 100 FMI 13 - Engine Controller (ECM) Power Out of Calibration |
heavy-equipment |
Minor |
View → |
100-16 |
Caterpillar Heavy Equipment
|
Caterpillar CID 100 FMI 16 - Engine Controller (ECM) Power Data Valid But Above Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
100-17 |
Caterpillar Heavy Equipment
|
Caterpillar CID 100 FMI 17 - Engine Controller (ECM) Power Data Valid But Below Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
100-3 |
Caterpillar Heavy Equipment
|
Caterpillar CID 100 FMI 3 - Engine Controller (ECM) Power Voltage Above Normal/Shorted High |
heavy-equipment |
Major |
View → |
100-31 |
Cat ET / EMCP 4.x
|
Caterpillar Cat ET Error Code CID 100 FMI 31 |
generator |
Moderate |
View → |
100-4 |
Caterpillar Heavy Equipment
|
Caterpillar CID 100 FMI 4 - Engine Controller (ECM) Power Voltage Below Normal/Shorted Low |
heavy-equipment |
Major |
View → |
100-5 |
Caterpillar Heavy Equipment
|
Caterpillar CID 100 FMI 5 - Engine Controller (ECM) Power Current Below Normal/Open Circuit |
heavy-equipment |
Major |
View → |
100-9 |
Cat ET / EMCP 4.x
|
Caterpillar Cat ET Error Code CID 100 FMI 9 |
generator |
Moderate |
View → |
102-13 |
Cat ET / EMCP 4.x
|
Caterpillar Cat ET Error Code CID 102 FMI 13 |
generator |
Moderate |
View → |
102-3 |
Cat ET / EMCP 4.x
|
Caterpillar Cat ET Error Code CID 102 FMI 3 |
generator |
Critical |
View → |
102-4 |
Cat ET / EMCP 4.x
|
Caterpillar Cat ET Error Code CID 102 FMI 4 |
generator |
Critical |
View → |
102-6 |
Cat ET / EMCP 4.x
|
Caterpillar Cat ET Error Code CID 102 FMI 6 |
generator |
Critical |
View → |
102-7 |
Cat ET / EMCP 4.x
|
Caterpillar Cat ET Error Code CID 102 FMI 7 |
generator |
Major |
View → |
102-8 |
Cat ET / EMCP 4.x
|
Caterpillar Cat ET Error Code CID 102 FMI 8 |
generator |
Major |
View → |
102-9 |
Cat ET / EMCP 4.x
|
Caterpillar Cat ET Error Code CID 102 FMI 9 |
generator |
Moderate |
View → |
105-13 |
Cat ET / EMCP 4.x
|
Caterpillar Cat ET Error Code CID 105 FMI 13 |
generator |
Moderate |
View → |
105-2 |
Cat ET / EMCP 4.x
|
Caterpillar Cat ET Error Code CID 105 FMI 2 |
generator |
Moderate |
View → |
105-3 |
Cat ET / EMCP 4.x
|
Caterpillar Cat ET Error Code CID 105 FMI 3 |
generator |
Critical |
View → |
105-31 |
Cat ET / EMCP 4.x
|
Caterpillar Cat ET Error Code CID 105 FMI 31 |
generator |
Moderate |
View → |
105-4 |
Cat ET / EMCP 4.x
|
Caterpillar Cat ET Error Code CID 105 FMI 4 |
generator |
Critical |
View → |
105-5 |
Cat ET / EMCP 4.x
|
Caterpillar Cat ET Error Code CID 105 FMI 5 |
generator |
Major |
View → |
105-6 |
Cat ET / EMCP 4.x
|
Caterpillar Cat ET Error Code CID 105 FMI 6 |
generator |
Critical |
View → |
105-7 |
Cat ET / EMCP 4.x
|
Caterpillar Cat ET Error Code CID 105 FMI 7 |
generator |
Major |
View → |
108-0 |
Cat ET / EMCP 4.x
|
Caterpillar Cat ET Error Code CID 108 FMI 0 |
generator |
Major |
View → |
108-13 |
Cat ET / EMCP 4.x
|
Caterpillar Cat ET Error Code CID 108 FMI 13 |
generator |
Moderate |
View → |
108-3 |
Cat ET / EMCP 4.x
|
Caterpillar Cat ET Error Code CID 108 FMI 3 |
generator |
Critical |
View → |
108-5 |
Cat ET / EMCP 4.x
|
Caterpillar Cat ET Error Code CID 108 FMI 5 |
generator |
Major |
View → |
108-6 |
Cat ET / EMCP 4.x
|
Caterpillar Cat ET Error Code CID 108 FMI 6 |
generator |
Critical |
View → |
108-7 |
Cat ET / EMCP 4.x
|
Caterpillar Cat ET Error Code CID 108 FMI 7 |
generator |
Major |
View → |
108-8 |
Cat ET / EMCP 4.x
|
Caterpillar Cat ET Error Code CID 108 FMI 8 |
generator |
Major |
View → |
108-9 |
Cat ET / EMCP 4.x
|
Caterpillar Cat ET Error Code CID 108 FMI 9 |
generator |
Moderate |
View → |
11-0 |
Caterpillar Heavy Equipment
|
Caterpillar CID 11 FMI 0 - Throttle Position Sensor Data Valid But Above Normal Range |
heavy-equipment |
Major |
View → |
11-13 |
Caterpillar Heavy Equipment
|
Caterpillar CID 11 FMI 13 - Throttle Position Sensor Out of Calibration |
heavy-equipment |
Minor |
View → |
11-16 |
Caterpillar Heavy Equipment
|
Caterpillar CID 11 FMI 16 - Throttle Position Sensor Data Valid But Above Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
11-17 |
Caterpillar Heavy Equipment
|
Caterpillar CID 11 FMI 17 - Throttle Position Sensor Data Valid But Below Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
11-18 |
Caterpillar Heavy Equipment
|
Caterpillar CID 11 FMI 18 - Throttle Position Sensor Data Valid But Below Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
11-2 |
Caterpillar Heavy Equipment
|
Caterpillar CID 11 FMI 2 - Throttle Position Sensor Data Erratic/Intermittent |
heavy-equipment |
Minor |
View → |
11-4 |
Caterpillar Heavy Equipment
|
Caterpillar CID 11 FMI 4 - Throttle Position Sensor Voltage Below Normal/Shorted Low |
heavy-equipment |
Major |
View → |
11-5 |
Caterpillar Heavy Equipment
|
Caterpillar CID 11 FMI 5 - Throttle Position Sensor Current Below Normal/Open Circuit |
heavy-equipment |
Major |
View → |
11-6 |
Caterpillar Heavy Equipment
|
Caterpillar CID 11 FMI 6 - Throttle Position Sensor Current Above Normal/Grounded Circuit |
heavy-equipment |
Major |
View → |
11-8 |
Caterpillar Heavy Equipment
|
Caterpillar CID 11 FMI 8 - Throttle Position Sensor Abnormal Frequency/Pulse Width |
heavy-equipment |
Major |
View → |
110-0 |
Caterpillar Heavy Equipment
|
Caterpillar CID 110 FMI 0 - Radiator Coolant Temperature Sensor Data Valid But Above Normal Range |
heavy-equipment |
Major |
View → |
110-1 |
Caterpillar Heavy Equipment
|
Caterpillar CID 110 FMI 1 - Radiator Coolant Temperature Sensor Data Valid But Below Normal Range |
heavy-equipment |
Major |
View → |
110-13 |
Caterpillar Heavy Equipment
|
Caterpillar CID 110 FMI 13 - Radiator Coolant Temperature Sensor Out of Calibration |
heavy-equipment |
Minor |
View → |
110-15 |
Caterpillar Heavy Equipment
|
Caterpillar CID 110 FMI 15 - Radiator Coolant Temperature Sensor Data Valid But Above Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
110-16 |
Caterpillar Heavy Equipment
|
Caterpillar CID 110 FMI 16 - Radiator Coolant Temperature Sensor Data Valid But Above Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
110-17 |
Caterpillar Heavy Equipment
|
Caterpillar CID 110 FMI 17 - Radiator Coolant Temperature Sensor Data Valid But Below Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
110-18 |
Caterpillar Heavy Equipment
|
Caterpillar CID 110 FMI 18 - Radiator Coolant Temperature Sensor Data Valid But Below Normal Operating Range (Moderately Severe) |
heavy-equipment |
Minor |
View → |
110-2 |
Caterpillar Heavy Equipment
|
Caterpillar CID 110 FMI 2 - Radiator Coolant Temperature Sensor Data Erratic/Intermittent |
heavy-equipment |
Minor |
View → |
110-3 |
Caterpillar Heavy Equipment
|
Caterpillar CID 110 FMI 3 - Radiator Coolant Temperature Sensor Voltage Above Normal/Shorted High |
heavy-equipment |
Major |
View → |
110-31 |
Cat ET / EMCP 4.x
|
Caterpillar Cat ET Error Code CID 110 FMI 31 |
generator |
Moderate |
View → |
110-4 |
Caterpillar Heavy Equipment
|
Caterpillar CID 110 FMI 4 - Radiator Coolant Temperature Sensor Voltage Below Normal/Shorted Low |
heavy-equipment |
Major |
View → |
110-5 |
Caterpillar Heavy Equipment
|
Caterpillar CID 110 FMI 5 - Radiator Coolant Temperature Sensor Current Below Normal/Open Circuit |
heavy-equipment |
Major |
View → |
110-6 |
Caterpillar Heavy Equipment
|
Caterpillar CID 110 FMI 6 - Radiator Coolant Temperature Sensor Current Above Normal/Grounded Circuit |
heavy-equipment |
Major |
View → |
110-7 |
Cat ET / EMCP 4.x
|
Caterpillar Cat ET Error Code CID 110 FMI 7 |
generator |
Major |
View → |
110-8 |
Caterpillar Heavy Equipment
|
Caterpillar CID 110 FMI 8 - Radiator Coolant Temperature Sensor Abnormal Frequency/Pulse Width |
heavy-equipment |
Major |
View → |
111-13 |
Caterpillar Heavy Equipment
|
Caterpillar CID 111 FMI 13 - Battery Voltage Out of Calibration |
heavy-equipment |
Minor |
View → |
111-15 |
Caterpillar Heavy Equipment
|
Caterpillar CID 111 FMI 15 - Battery Voltage Data Valid But Above Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
111-17 |
Caterpillar Heavy Equipment
|
Caterpillar CID 111 FMI 17 - Battery Voltage Data Valid But Below Normal Operating Range (Least Severe) |
heavy-equipment |
Info |
View → |
111-2 |
Caterpillar Heavy Equipment
|
Caterpillar CID 111 FMI 2 - Battery Voltage Data Erratic/Intermittent |
heavy-equipment |
Minor |
View → |
111-3 |
Caterpillar Heavy Equipment
|
Caterpillar CID 111 FMI 3 - Battery Voltage Voltage Above Normal/Shorted High |
heavy-equipment |
Major |
View → |